Chassis and Module Specifications
-
LPU Slots: 4
-
MPU Slots: 2
-
SFU Slots: 2
-
Fan Slots: 2
-
Power Module Slots: 4
-
CMU Slots: 2
Port Density per Chassis
-
192 × FE
-
192 × GE
-
192 × 10GE
-
160 × 25GE
-
96 × 40GE
-
96 × 100GE
Installation
-
Compatible with N66E or N68E cabinets
-
Supports one or two chassis per cabinet
-
Cluster Switch System (CSS): Service port clustering supported
Power Specifications
DC Input
-
Rated voltage: –48 V DC to –60 V DC
-
Maximum voltage range: –40 V DC to –72 V DC
AC Input
-
Rated voltage: 110 V AC / 220 V AC, 50/60 Hz
-
Maximum voltage range: 90 V AC to 290 V AC, 47–63 Hz
-
Note: Maximum output power reduces by 50% when input is 90–175 V AC
High-Voltage DC Input (3000 W AC)
-
Rated voltage: 240 V DC
-
Maximum voltage range: 190 V DC to 290 V DC
Physical Specifications
-
Dimensions (H × W × D, without rack brackets):
-
With cable management frames (10U high): 441.7 × 442 × 585 mm (17.39 × 17.4 × 23.0 in.)
-
Without cable management frames (10U high): 441.7 × 442 × 517.4 mm (17.39 × 17.4 × 20.37 in.)
-
-
Weight:
-
Empty: 24.5 kg (54 lb)
-
Fully configured: 66 kg (145.5 lb)
-
Reliability and Availability
-
Mean Time Between Failures (MTBF): 33.38 years
-
Mean Time to Repair (MTTR): 2 hours
-
Availability: 0.99999658
Environmental Specifications
-
Operating Temperature & Altitude:
-
–60 m to +1800 m (–197 ft to 5906 ft): 0°C to 45°C (32°F to 113°F)
-
1800 m to 4000 m (5906 ft to 13123 ft): Operating temperature decreases by 1°C (1.8°F) per 220 m (722 ft.) altitude increase
-
4000 m (13123 ft): 0°C to 35°C (32°F to 95°F)
-
-
Relative Humidity: 5% to 95% RH, non-condensing
-
Storage Temperature: –40°C to +70°C (–40°F to +158°F)
-
Storage Altitude: < 5000 m (16404 ft)
-
Noise (sound power, normal temperature): ≤ 78 dB(A)
Certification
-
EMC certification
-
Safety certification
-
Manufacturing certification